MICROMO offers an extensive line of brush type DC motors ranging from 0.5 mW to 500 Watts in power. Here are some general notes on the application of our DC motors and some general guidelines for care and handling of precision motors.

Audible Noise: Audible noise is a concern in some types of motor applications. In many medical applications like infusion pumps or prosthetic devices, the patient can be very sensitive to the noise disturbance. Good design practice requires that the noise be limited as much as possible. In large machines, the combination of hundreds of DC motors and gears operating simultaneously can be very loud and distracting to the employees who have to work in close proximity to the machine

Quality Components: Probably the best method of insuring low audible noise in motors is to specify quality components. Motors using cheap or poorly fitted bearings are more likely to be noisy. Poorly designed or loose fitting brush sets can contribute to audibly noisy commutation. Manufacturers of inexpensive, high volume motors cannot reasonably be expected to concern themselves with quiet operation beyond some minimum standard, and the use of such motors in applications where quiet operation is important should be considered carefully. The designer must consider whether low cost takes precedence over quiet operation in the priorities of the customer.

Bearing Choice: The use of ball bearings without pre-load is a potential source of audible noise. Where the specific application permits, ball bearings should be pre-loaded. This means that the balls will not be able to move axially in the race and cause the minute intermittent rattling that can sometime be associated with unpreloaded ball bearings. Smaller ball bearings can be sensitive to heavy shaft loads. They are easily damaged during press fitting added components and by short radial or axial overloads. Care should be taken not to exceed the shaft loading ranges specified in the datasheets. A damaged ball bearing can be a significant source of audible noise and can effect motor life.

Sintered sleeve bearings are a very good choice when limiting audible noise if the application does not require the motor to endure significant continuous or intermittent changes in the shaft loading characteristics. The shaft of the motor actually rides on a thermodynamic film of lubrication and the reduced friction can limit audible noise. If the bearing is overloaded radially, however, this film breaks down and the shaft will grind the bearing down causing audible noise and reducing the operational lifetime of the motor.

Vibration: Rotor vibration can be a significant source of audible noise. Vibration and noise increases with speed. Even a slight imbalance in the rotor can cause major vibrations at speeds of 10,000rpm. FAULHABER Group DC motors have extremely low rotor vibration and an added precision balance can be specified to all but eliminate the effect of motor vibration on audible noise.

Brush Options: Copper-graphite type brushes tend to be both audibly and electrically noisier than precious metal systems. Graphite based brushes are capable of withstanding considerably higher current densities, however, and they are often required in an application for that reason. Where a choice is available for a specific application and audible noise is important, precious metal brushes are the better choice. MICROMO and the FAULHABER Group make every attempt to limit the brush noise in their motors with copper graphite commutation. The brushes are preground to fit the commutator profile and all motors are "burned in" overnight to smooth out the surface of the brushes, thereby reducing noise and increasing overall brush contact for maximum performance.

Electromagnetic Interference (EI)

DC motors are a source of electrical as well as audible noise. EMI (electro-magnetic interference) can be radiated by motor terminals and lead wires and may cause problems with other components in the vicinity of the motor. It is also possible for spikes to be coupled onto data lines or output lines from encoders. The result can be false data or encoder information. There are a number of methods that can be used to minimize EMI in motor applications. Like many other considerations in DC motor applications, each has its advantages and disadvantages and must be evaluated within the context of the application.

Motor Commutation: The most common source of EMI problems is the commutation of motors. At each commutation point, when the brush breaks contact with a commutator segment, the energy stored in the motor winding as a magnetic field causes an arc or voltage spike between the brush and the commutator segment. This occurs not only during normal commutation but also in situations where the brushes "bounce" on the rotating commutator. Coreless DC motors are typically less electrically noisy than iron core DC motors because of the lower armature inductance which in turn reduces the level of the arc energy. This arcing can be further mitigated with the addition of a capacitor ring, which serves to dissipate the energy through a capacitor and resistor series back into the motor coil.

Quality Components: We can't stress enough the importance of using quality components in any motor design. As was the case with audible noise, the use of cheap, poorly constructed motors adds to the electrical noise problem. "Open case" motors do not effectively block EMI radiated from the coil windings. Poorly fitted brush holders and inadequate brush tension contribute to radiated EMI as well.

Coreless motors: Coreless DC motors have much lower armature inductance than iron-core motors of comparable size. Since armature inductance is the primary cause of EMI problems, minimizing it through selection of coreless motors is recommended where EMI is a critical factor.

Lead Wires and Shielding: Motor lead wires should be placed as close together as possible so that EMI radiated from the two leads can cancel each other. This canceling effect can be improved by using so-called "twisted pairs" where the positive and negative lead wires are twisted together. Motor leads should be physically separated from data lines or encoder outputs to reduce the possibility of coupling motor noise onto them. This means that when using shielded pigtails, the feedback lines should be shielded separately from the motor leads. If noise is still causing problems with the encoder signals than it may be time to consider using a differential encoder to eliminate the effect of interference on the encoder. For information on the various types of shielding available, please contact a MICROMO applications engineer.  PWM switching noise is another source of EMI problems. Most commonly, PWM switching results in radiated noise from motor lead wires. Shielding and lead wire placement can also help mitigate the effect of PWM generated EMI.

Passive components: EMI problems can often be significantly reduced by the simple act of installing a capacitor across the motor terminals. In some types of applications, this method may not be suitable since a resonant circuit is created which can cause "ringing" problems near resonant frequencies. In these instances, an RC snubber network across the motor terminals may be more effective. Component values are not critical for motors driven with DC, but care must be taken in selecting components for PWM driven systems.

Motor Service Life

Operating Point: In most applications, the torque and speed demands placed upon a DC motor determine its overall operational lifetime. As the torque requirements on the motor increase, the current through the armature increases proportionally, thus increasing the current density at the brush-commutator interface. High current densities promote electro-erosion of brush and commutator materials, a limiting factor in motor service life. In addition, high rotational speeds shorten motor service life by accelerating mechanical wear.

Although each application has its own specific requirements to be addressed, it is usually advisable to operate a DC motor with precious metal brushes and commutator continuously at no more than 1/3 of its rated stall torque. Motors with graphite on copper commutation systems should be run continuously at no more than 1/2 of the motor's rated stall torque. These recommendations attempt to maximize motor service life. Some applications may not require the maximum lifetime that the motor has to offer. The applications engineers at MICROMO Electronics can help you determine the necessary service life and optimize the motor choice to fit the application.

Rotor Inductance: One of the factors limiting brush and commutator life is the inductance of the motor armature. During commutation, when current flows through a particular coil winding there is storage of energy in the form of a magnetic field. When the motor commutates and the current flow is switched to another winding, the magnetic field collapses and the resulting discharge of energy causes an arc between the commutator and brush. This arcing accelerates electro-erosion and decreases motor life. One could, theoretically, reduce the armature inductance of the motor windings by decreasing the number of turns in each armature segment. This lowers the torque constant of the motor, however, which increases the motor current for a given torque and, therefore, increases the current density at the brush-commutator interface. This is not recommended. To reduce the affect of inductance and arcing on motor lifetime, FAULHABER offers most motor series with a capacitor ring mounted to the commutator. The ring provides the equivalent effect of each winding connected in parallel with a small capacitor and resistor. The collapse of the magnetic field during commutation then serves to charge the capacitor rather than creating an arc between brush and commutator. The stored energy is released and dissipated back into the next coil phase in the commutation sequence. This technique, while slightly increasing the electrical time constant of the motor, dramatically increases motor service life. Make sure to inquire with the applications engineers at MICROMO to find out more about the use of capacitors to increase motor life.

Drive Profiles: Operating conditions other than torque and speed also affect service life. The application may require frequent starting and stopping or reversals of direction. Both situations result in periods of high current density and a resulting shortening of service life. A similar effect is seen in applications where pulse width modulated (PWM) drives are used. If the PWM frequency is too low, the motor is constantly accelerating and decelerating with an accompanying increase in current density. As a general rule, PWM frequencies of 20 KHz or higher are recommended for ironless core motors.

Environmental Considerations: Environmental conditions can have a profound effect on motor service life. One good example is the rapid drying and wear of graphite-based brushes in a vacuum or very dry environment. Very warm and dry conditions also hasten the breakdown of bearing and commutator lubricants. The ambient temperature has a cumulative effect on the motor's operational temperature and can lower performance by limiting the operational temperature range of the motor. External cooling by contact, air or forced air can produce significant gains in motor performance. At the opposite extreme, very cold conditions increase the viscosity of lubricants and cause the motor to run at a higher current. MICROMO has a wide variety of standard modifications for motors that will be experiencing temperatur or pressure extremes. These modifications usually consist of a change in the bearing and commutation lubrication but can also include special coil coatings for high temperature operation. Please consult with a MICROMO applications engineer to learn more about how to modify a motor for use in extreme temperature or pressures.

Shaft Loading: Shock loads and vibration contribute to the tendency of the brushes to "bounce" on the commutator, thus causing arcing and accelerated electro-erosion. Shock loads and vibration also accelerate bearing wear. Excessive axial or radial shaft loads decrease the life of bearings, sometimes significantly. MICROMO offers a variety of bearing options to compensate for different load types. In continuous duty applications with low radial shaft loads, sintered bearings are the inexpensive choice. For increased radial loads, ceramic bearings are available. Ball bearings are typically specified when the application calls for higher radial and axial shaft loads. Consult with a MICROMO applications engineer to determine which bearings type is most suitable for your application.

Quality and Workmanship: Lifetime performance is enhanced considerably by high standards of workmanship and quality. MICROMO and the FAULHABER Group are committed to producing the world's highest quality miniature drive systems, components and controls. Group-wide ISO certification and precise component design and assembly all help to maximize product lifetimes and value to the customer.

下一篇: PLC、DCS、FCS三大控

上一篇: 索爾維全系列Solef?PV

推薦產品

更多
主站蜘蛛池模板: 深圳市宏康仪器科技有限公司-模拟高空低压试验箱-高温防爆试验箱-温控短路试验箱【官网】 | 连栋温室大棚建造厂家-智能玻璃温室-薄膜温室_青州市亿诚农业科技 | 小型数控车床-数控车床厂家-双头数控车床 | 有源电力滤波装置-电力有源滤波器-低压穿排电流互感器|安科瑞 | 中细软知识产权_专业知识产权解决方案提供商 | 烟台游艇培训,威海游艇培训-烟台市邮轮游艇行业协会 | 北京征地律师,征地拆迁律师,专业拆迁律师,北京拆迁律师,征地纠纷律师,征地诉讼律师,征地拆迁补偿,拆迁律师 - 北京凯诺律师事务所 | 进口便携式天平,外校_十万分之一分析天平,奥豪斯工业台秤,V2000防水秤-重庆珂偌德科技有限公司(www.crdkj.com) | 开锐教育-学历提升-职称评定-职业资格培训-积分入户 | 金属雕花板_厂家直销_价格低-山东慧诚建筑材料有限公司 | 禹城彩钢厂_钢结构板房_彩钢复合板-禹城泰瑞彩钢复合板加工厂 | 自动气象站_农业气象站_超声波气象站_防爆气象站-山东万象环境科技有限公司 | 微波消解仪器_智能微波消解仪报价_高压微波消解仪厂家_那艾 | 东莞工厂厂房装修_无尘车间施工_钢结构工程安装-广东集景建筑装饰设计工程有限公司 | 铣刨料沥青破碎机-沥青再生料设备-RAP热再生混合料破碎筛分设备 -江苏锡宝重工 | ET3000双钳形接地电阻测试仪_ZSR10A直流_SXJS-IV智能_SX-9000全自动油介质损耗测试仪-上海康登 | 上海璟文空运首页_一级航空货运代理公司_机场快递当日达 | 定硫仪,量热仪,工业分析仪,马弗炉,煤炭化验设备厂家,煤质化验仪器,焦炭化验设备鹤壁大德煤质工业分析仪,氟氯测定仪 | 环比机械| 江西自考网-江西自学考试网| 超声波焊接机_超音波熔接机_超声波塑焊机十大品牌_塑料超声波焊接设备厂家 | 乙炔气体报警装置|固定式氯化氢检测仪|河南驰诚电气百科 | 全自动五线打端沾锡机,全自动裁线剥皮双头沾锡机,全自动尼龙扎带机-东莞市海文能机械设备有限公司 | 衡阳耐适防护科技有限公司——威仕盾焊接防护用品官网/焊工手套/焊接防护服/皮革防护手套 | 全自动固相萃取仪_高通量真空平行浓缩仪-勤业永为 | 东莞螺丝|东莞螺丝厂|东莞不锈钢螺丝|东莞组合螺丝|东莞精密螺丝厂家-东莞利浩五金专业紧固件厂家 | 密集架|电动密集架|移动密集架|黑龙江档案密集架-大量现货厂家销售 | 杭州实验室尾气处理_实验台_实验室家具_杭州秋叶实验设备有限公司 | 集装箱箱号识别_自重载重图像识别_铁路车号自动识别_OCR图像识别 | 大型多片锯,圆木多片锯,方木多片锯,板材多片锯-祥富机械有限公司 | 电池挤压试验机-自行车喷淋-车辆碾压试验装置-深圳德迈盛测控设备有限公司 | 磨煤机配件-高铬辊套-高铬衬板-立磨辊套-盐山县宏润电力设备有限公司 | 广东机电安装工程_中央空调工程_东莞装饰装修-广东粤标建设有限公司 | sus630/303cu不锈钢棒,440C/430F/17-4ph不锈钢研磨棒-江苏德镍金属科技有限公司 | 哈尔滨治「失眠/抑郁/焦虑症/精神心理」专科医院排行榜-京科脑康免费咨询 一对一诊疗 | 贴片电感_贴片功率电感_贴片绕线电感_深圳市百斯特电子有限公司 贴片电容代理-三星电容-村田电容-风华电容-国巨电容-深圳市昂洋科技有限公司 | 泥浆在线密度计厂家-防爆数字压力表-膜盒-远传压力表厂家-江苏大亚自控设备有限公司 | 哈尔滨京科脑康神经内科医院-哈尔滨治疗头痛医院-哈尔滨治疗癫痫康复医院 | 大白菜官网,大白菜winpe,大白菜U盘装系统, u盘启动盘制作工具 | 防腐木批发价格_深圳_惠州_东莞防腐木厂家_森源(深圳)防腐木有限公司 | 不锈钢反应釜,不锈钢反应釜厂家-价格-威海鑫泰化工机械有限公司 不干胶标签-不干胶贴纸-不干胶标签定制-不干胶标签印刷厂-弗雷曼纸业(苏州)有限公司 |