這是我的一次跨國(guó)長(zhǎng)途技能效勞中回復(fù)的郵件......
>Hi Cen,
>
>after adjustment belt tension on the capstan, the take up works properly.
>Thank you very much for your help.
> Regards! Kaz
----- Original Message -----
From: "Zane Huang"
To: "KM-ELECTRO Morski Kazimierz"
Sent: Monday, February 17, 2014 3:39 PM
Subject: Re: Take up 5/4
> Hi Kaz
>
> Long time haven't seen each other, miss you much.
> about the problem, I checked the historical data recorded in the system just now,
>and found some difference between take up #3 and take up #4.
> Pls see the attach files, screenshot pictures.
> It seems that the problem started from afternoon Feb. 10th.
> The take up system has auto-change function according to actual winding diameter of the reel.
> d = Vset/(Pi*RPMact)
> According to the recorded curves, the spool rotation speed must be much lower than it should
> be normally.
> Maybe this can help you solve the problem.
> Any further information, pls send it to me.
> Good luck !
> Huang Cen
-----Original Message-----
From: KM-ELECTRO Morski Kazimierz
Sent: Monday, February 17, 2014 7:16 PM
To: Zane Huang
Subject: Take up 5/4
> Hi Cen,
>
> Happy New Year!!!
> Have problems with take up 5/4.
> Random time 5-15 minutes to automatic spool change ( visible on LCD), take up change spool ,
> both on the left and right side...any ideas why
> TeamViewer id: *********
> password: **********
> Best regards! Kaz
2014年的新年長(zhǎng)假剛過(guò)的一個(gè)周一,剛上班沒(méi)兩天,悉數(shù)如同還沉浸在假日的空氣里,稀有的悠閑。快下班前俄然接到一個(gè)配套客戶主管工程師的電話,說(shuō)在12年出口波蘭的一套由我計(jì)劃的設(shè)備出疑問(wèn)無(wú)法出產(chǎn)了,本地的工程師忙活了一禮拜沒(méi)搞定,讓我預(yù)備一下立刻去波蘭。空氣一下有點(diǎn)小嚴(yán)峻,啥狀況?設(shè)備確實(shí)是我計(jì)劃的,也是我親身去波蘭調(diào)試的,那兒的設(shè)備主管Kaz也是個(gè)履歷豐厚的老工程師,他幫忙我調(diào)試,臨走前我把家底兒都奉告給他了,所以設(shè)備查驗(yàn)都快兩年了傳聞一向不斷地在出產(chǎn),歷來(lái)沒(méi)找過(guò)我。如何一頃刻間就搞不定了呢?出啥大事兒啦?掛斷電話疑問(wèn)了幾分鐘,緊接著Kaz的郵件也到了,他描繪了下缺點(diǎn)的景象,并告訴我長(zhǎng)途登錄設(shè)備的賬號(hào)暗碼,當(dāng)年在調(diào)試的時(shí)分,Kaz就把設(shè)備操控體系的上位機(jī)(IPC547D有雙網(wǎng)卡)接入他們公司的網(wǎng)絡(luò),設(shè)備了Teamviewer長(zhǎng)途聯(lián)機(jī)軟件并做了查驗(yàn),如今總算派上用場(chǎng)了。
刻不容緩,從速登錄上去看看吧。翻開(kāi)了久別而又了解的畫面,設(shè)備總共4個(gè)工位,3個(gè)都在正常出產(chǎn),僅有4號(hào)工位停機(jī)了,心定了,有些疑問(wèn),沒(méi)那么嚴(yán)峻。接著,查看了悉數(shù)操作界面,參數(shù)界面,報(bào)警信息,體系確診信息沒(méi)有發(fā)現(xiàn)任何的反常,乃至在前史報(bào)警歸檔中都沒(méi)有找到一條有關(guān)于設(shè)備的缺點(diǎn)信息,啥啥啥都是好好的嘛,搞啥鬼?轉(zhuǎn)念一想,以我對(duì)Kaz的了解,他是不會(huì)簡(jiǎn)略瞎說(shuō)的,必定是有疑問(wèn)存在,但這時(shí)我也能夠很自傲地?cái)喽ǎ秉c(diǎn)與電氣操控體系之間應(yīng)當(dāng)聯(lián)絡(luò)不大。一看時(shí)刻,都7點(diǎn)多了,先下班回家就餐吧。
一路上都在思考著疑問(wèn)的各種或許性,回到家也是匆促扒了幾口飯,就匆促到書房翻開(kāi)電腦從頭連線登錄了。又細(xì)心過(guò)了一遍操作界面,參數(shù)界面,報(bào)警和確診信息,前史缺點(diǎn)記載,沒(méi)有發(fā)現(xiàn)任何有價(jià)值的信息,一同也再次斷定操控體系沒(méi)有疑問(wèn)。接著翻開(kāi)了出產(chǎn)進(jìn)程技能參數(shù)的前史記載,查看了4號(hào)工位的工況曲線,因?yàn)殚_(kāi)端在體系程序計(jì)劃時(shí)特意留下了特征數(shù)據(jù),前史歸檔數(shù)據(jù)也照實(shí)地記載下并在曲線上反映了出來(lái),4號(hào)工位近2天的記載確實(shí)如Kaz所述無(wú)法正常作業(yè)。看到這兒我底子上了解了4號(hào)工位不能正常作業(yè)的要素,這是個(gè)高速線材收卷操控體系,恒線速恒張力操控,體系計(jì)劃有超卷徑維護(hù)功用,也便是當(dāng)實(shí)習(xí)作業(yè)線速度與實(shí)習(xí)收線軸轉(zhuǎn)速的比值在一段時(shí)刻內(nèi)接連跨過(guò)某個(gè)(滿卷)設(shè)定值時(shí),操控體系就會(huì)疏忽計(jì)長(zhǎng)功用的核算值,然后直接主動(dòng)觸發(fā)主動(dòng)換卷功用。這功用是用來(lái)避免滿卷再繞以及排線設(shè)備出疑問(wèn)后致使在一點(diǎn)固定卷繞的景象。但實(shí)習(xí)上4號(hào)工位都是在未滿卷狀況下就觸發(fā)了主動(dòng)換盤功用,僅有的闡明便是收卷軸的轉(zhuǎn)速低了,收線軸的折算線速度曲線對(duì)照也反映出了這個(gè)疑問(wèn)。
圖一:3號(hào)工位正常的線速度曲線
圖二:4號(hào)工位反常線速度曲線1
圖三:4號(hào)工位反常線速度曲線2
終究是啥致使收線軸轉(zhuǎn)速慢了,張力操控是正常的,莫非是行線速度慢了?牽引是開(kāi)環(huán)操控的,盡管我計(jì)劃之初劇烈懇求選用閉環(huán)計(jì)劃,但配套客戶仍是以各種理由回絕了,因而牽引的回來(lái)線速度實(shí)習(xí)是驅(qū)動(dòng)器斜坡函數(shù)的輸出值,這也是收線軸的線速度給定。我盡管劇烈的置疑,但沒(méi)有任何的依據(jù)能夠證實(shí)牽引線速度出了疑問(wèn),再說(shuō)了線速度是首要的技能參數(shù),對(duì)商質(zhì)量量有嚴(yán)峻的影響,Kaz那兒也沒(méi)給我這方面的信息反響,也只好放一放,從別的方向找要素了。
時(shí)刻敏捷的曩昔了,轉(zhuǎn)瞬已是午夜了,仍是沒(méi)有條理,盡管我很了解電氣操控體系沒(méi)有疑問(wèn),但我也沒(méi)找到了解的依據(jù),明日讓我如何跟客戶闡明呢?幾個(gè)小時(shí)的燒腦,讓我有些困了,這時(shí)俄然網(wǎng)速一頃刻間立刻很多,長(zhǎng)途端上位機(jī)的反響也立刻很多,我精力一振,把前史曲線往前翻了很多天,發(fā)現(xiàn)4號(hào)工位的出產(chǎn)一向都是正常的,僅僅在一個(gè)星期前有過(guò)一次10幾個(gè)小時(shí)較長(zhǎng)時(shí)刻的停機(jī)進(jìn)程,再開(kāi)機(jī)出產(chǎn)就不正常了,這時(shí)期發(fā)作了啥?仍是先發(fā)個(gè)郵件問(wèn)問(wèn)Kaz吧,所以我就回了這篇文章開(kāi)端的那封郵件…..
第二天,頂住了配套商打來(lái)的好幾通敦促電話,也是在快下班前收到了Kaz的回復(fù),悉數(shù)都了解了,我其時(shí)最想做的便是把那個(gè)趾高氣昂的配套商主管工程師摁到馬桶里去,開(kāi)端便是他頑固否定牽引的閉環(huán)操控計(jì)劃的….,疑問(wèn)一處理,波蘭天然也就去不成了,還有點(diǎn)小悵惘!
這樸素是一次偶爾,也能夠算是我正真意義上的關(guān)于設(shè)備直接做跨國(guó)長(zhǎng)途技能確診的一次實(shí)戰(zhàn)履歷,在2年多前。時(shí)至今日,長(zhǎng)途幫忙確診與調(diào)試盡管現(xiàn)已習(xí)以為常,但這大多是在現(xiàn)場(chǎng)有人幫忙的,而長(zhǎng)途直接面臨機(jī)器設(shè)備的調(diào)試確診正本并不如期望中的那么簡(jiǎn)略,幾個(gè)方面的預(yù)備作業(yè)要做好,鄙人面具體介紹:
長(zhǎng)途直接面臨機(jī)器設(shè)備的調(diào)試確診的預(yù)備作業(yè)
1、要有預(yù)先構(gòu)架好的網(wǎng)絡(luò),支撐從Internet直接拜訪到客戶工廠里的設(shè)備。
①現(xiàn)場(chǎng)設(shè)備有PC的,能夠選用TEAMVIEWER等軟件經(jīng)過(guò)長(zhǎng)途桌面操控的辦法進(jìn)行確診和調(diào)試,現(xiàn)場(chǎng)PC經(jīng)過(guò)客戶網(wǎng)絡(luò)能夠上網(wǎng),不需求固網(wǎng)IP地址(本案即此例)。
②現(xiàn)場(chǎng)沒(méi)有PC的,能夠經(jīng)過(guò)選用VPN客戶端路由器、3G/4G移動(dòng)網(wǎng)絡(luò)、客戶的有線網(wǎng)絡(luò)以及VPN路由器效勞器,把不在一地的plc與工程師調(diào)試站拉到了同一個(gè)內(nèi)網(wǎng)中。現(xiàn)場(chǎng)客戶端只需能上網(wǎng)即可,VPN路由器效勞器側(cè)需求固網(wǎng)IP地址。
2、PLC及PC體系要裝備有接入長(zhǎng)途調(diào)試及確診的通訊接口,應(yīng)盡量與用于現(xiàn)場(chǎng)設(shè)備通訊的接口分隔及阻隔。
3、有了以上的硬件條件后,設(shè)置并注冊(cè)長(zhǎng)途接入賬號(hào),事前做好聯(lián)接查驗(yàn),以備不時(shí)之需。
4、假定是到現(xiàn)場(chǎng)PC級(jí)的長(zhǎng)途確診(如本案),那么現(xiàn)場(chǎng)PC所能夠供給的設(shè)備信息就尤為首要了,這通常需求經(jīng)過(guò)對(duì)現(xiàn)場(chǎng)的PC和plc編程來(lái)結(jié)束,通常都是將PLC上的信息都盡量傳送到現(xiàn)場(chǎng)的PC上,越悉數(shù)越完善越好,這就需求事前縝密地思考與預(yù)備。乃至現(xiàn)場(chǎng)PC也要設(shè)備必要的編程組態(tài)軟件,經(jīng)過(guò)長(zhǎng)途桌面操控辦法操作編程軟件對(duì)網(wǎng)絡(luò)中的PLC進(jìn)行調(diào)試確診。
下一篇: PLC、DCS、FCS三大控
上一篇: MATLAB和Simulink在航